On Windows 64-bit operating systems, when you launch the ODBC Data Source Administrator to create a ODBC connection to your database, you create a 64-bit version of the connection that is not compatible with the Netop Security Server. The Security Server is a 32-bit application that requires that the ODBC connection be created using the 32-bit version of the ODBC Data Source Administrator. You may recognize this issue because although an ODBC connection has been created in Windows the ODBC connection is not visible in the Security Server or Security Manager interface when you try to log on to the the database.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article